Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Contractor Pricing
Schluter DITRA HEAT 120 V Heating Cable E-HK
$20174 USD
Unit price
/
Unavailable
Shipping calculated at checkout.
Brand: Schluter Systems
| SKU: 2449-35.3 ft.
| MPN:
Shipping & Delivery
Shipping & Delivery
- $13.95 Flat Rate shipping for orders under $500 (Other options at checkout)
- Same-day shipping cut-off time for ground orders for CD stock items is 3:00 PM ET
- Same-day shipping cut-off time for expedited orders for CD stock items is 12:00 PM ET
- Shipping time is calculated by business days. Weekends do not count.
- For Freight Items See Policy Here
Schluter DITRA-HEAT-E-HK 120 Volt Heating Cable
Schluter DITRA-HEAT-E-HK are twisted pair heating cables designed for integration with the DITRA-HEAT uncoupling membrane in interior floor warming applications.
Features
-
Provides electric floor warming for use beneath tile, stone, or other resilient floor coverings
(e.g. LVT) - Cables snap into the membrane; clips and fasteners are not required
- No self-levelers required to encapsulate the cables; installation time significantly reduced
- No return to thermostat required
- Produces virtually zero electromagnetic fields
Schluter 120 V DITRA-HEAT-E-HK Specifications | |||||||
Model | Heating Cable Length | Regular 3 Stud Spacing Coverage | Alternating 3-2 Stud Spacing Coverage | Total Power | Regular 3 Stud Power Delivery | Alternating 3-2 Stud Power Delivery | Currency |
DHE HK 120 11 |
35.3 ft (10.8 m) |
10.7 ft² (1.0 m2) |
8.9 ft² (0.8 m2) |
135 W |
12.6 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
1.1 amps |
DHE HK 120 16 |
52.9 ft (16.1 m) |
16.0 ft² (1.5 m2) |
13.3 ft² (1.2 m2) |
203 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
1.7 amps |
DHE HK 120 21 |
70.5 ft (21.5 m) |
21.3 ft² (2.0 m2) |
17.8 ft² (1.7 m2) |
270 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
2.3 amps |
DHE HK 120 27 |
88.2 ft (26.9 m) |
26.7 ft² (2.5 m2) |
22.2 ft² (2.1 m2) |
338 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
2.8 amps |
DHE HK 120 32 |
105.8 ft (32.2 m) |
32.0 ft² (3.0 m2) |
26.7 ft² (2.5 m2) |
405 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
3.4 amps |
DHE HK 120 38 |
124.1 ft (37.8 m) |
37.5 ft² (3.5 m2) |
31.3 ft² (2.9 m2) |
475 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
4.0 amps |
DHE HK 120 43 |
141.1 ft (43.0 m) |
42.7 ft² (4.0 m2) |
35.6 ft² (3.3 m2) |
540 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
4.5 amps |
DHE HK 120 51 |
169.8 ft (51.8 m) |
51.4 ft² (4.8 m2) |
42.8 ft² (4.0 m2) |
650 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
5.4 amps |
DHE HK 120 64 |
212.9 ft (64.9 m) |
64.4 ft² (6.0 m2) |
53.7 ft² (5.0 m2) |
815 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
6.8 amps |
DHE HK 120 73 |
240.2 ft (73.2 m) |
72.7 ft² (6.8 m2) |
60.6 ft² (5.6 m2) |
920 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
7.7 amps |
DHE HK 120 83 |
275.5 ft (84.0 m) |
83.3 ft² (7.7 m2) |
69.4 ft² (6.5 m2) |
1055 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
8.8 amps |
DHE HK 120 92 |
303.0 ft (92.4 m) |
91.7 ft² (8.5 m2) |
76.4 ft² (7.1 m2) |
1160 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
9.7 amps |
DHE HK 120 102 |
336.9 ft (102.7 m) |
101.9 ft² (9.5 m2) |
84.9 ft² (7.9 m2) |
1290 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
10.7 amps |
DHE HK 120 113 |
372.2 ft (113.4 m) |
112.6 ft² (10.5 m2) |
93.8 ft² (8.7 m2) |
1425 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
11.9 amps |
DHE HK 120 134 |
444.0 ft (135.3 m) |
134.3 ft² (12.5 m2) |
111.9 ft² (10.4 m2) |
1700 W |
12.7 Watts/ft² (136 Watts/m²) |
15.2 Watts/ft² (164 Watts/m²) |
14.2 amps |
Common Questions
Does DITRA-HEAT need a dedicated circuit?
Does DITRA-HEAT need a dedicated circuit?
A dedicated circuit is required.Select either 120V or 240V heating cable according to power supply.
Can I cut the thermostat wire on DITRA-HEAT?
Never CUT the heating cable. This could change the cable resistance and could lead to a fire. WARRANTY DISClAIMER: Damage to the DITRA-HEAT-E-HK heating cables voids the Schluter®-DITRA-HEAT 10-Year limited Warranty